Intuvo 9000 Gas Chromatograph (GC) System
Intuvo 9000 GC System
The Intuvo 9000 Gas Chromatography (GC) System is designed for?fast gas chromatography and high throughput while simplifying your laboratory workflow. Eliminate column maintenance and change columns in less than a minute with Intuvo's click-and-run connections. Ballistic direct column heating offers faster GC cycle times and improves reproducibility.
Intuvo's built-in intelligence reduces operational and maintenance costs through self-guided diagnostic troubleshooting and early maintenance feedback. Smart Keys identify the exact instrument configuration and column parameters to reduce user error.
Intuvo's built-in intelligence reduces operational and maintenance costs through self-guided diagnostic troubleshooting and early maintenance feedback. Smart Keys identify the exact instrument configuration and column parameters to reduce user error.
- GC Systems
Request a Quote
Product Details
Features
- Guard Chips prevent column contamination, protecting downstream components and increasing column life
- Intuvo no-trim GC columns require no maintenance
- Direct heating oven delivers linear and repeatable temperature ramps from 30 °C to 450 °C at 250 °C/min
- Ferrule-free, click-and-run connections allow any operator, regardless of experience, to make completely leak-free connections
- Innovative flow path provides the ability to configure the GC flow path as needed, making backflush installation simple
- Smart ID Keys attached to critical flow path components provide information such as configuration and column age with default parameters for configuration
- Intelligent troubleshooting routines diagnose GC system problems by measuring over 100 parameters in real time and provide a step-by-step solution guide in an easy-to-read format
- Large touchscreen control with the ability to deliver instrument information wirelessly through secure networks
- Uses less than half the power of a conventional GC and can be plugged into any outlet without changing the wiring of the lab
- Ideal platform for high-throughput or high-speed gas chromatography with fast heating and cool down
- Smaller footprint than most lab GC systems with a similar range of functionality and performance to optimize valuable bench space
- Gas Saver, smaller column dimensions, and faster cycle times can result in less helium consumption compared to conventional GC systems
- Compatible with Agilent 5977, 7000, and 7010 mass spectrometer systems
- Independently audited for environmental impact throughout the product lifecycle, received My Green Labs ACT (Accountability, Consistency, Transparency) label
Specifications
Capillary Flow Technology (CFT) |
|
Detectors |
|
Dimensions (WxDxH) |
|
Dual Simultaneous Injection |
|
GC Detector MDLs |
|
GC Diagnostics - Leak Check |
|
GC/MS Compatibility |
|
Inlets |
|
Maximum Temperature Ramp Rate |
|
Operating Temperature Range |
|
Oven Cool Down |
|
Peak Area Repeatability |
|
Retention Time Repeatability |
|
Typical Pressure Control |
|
Valves |
|
Technology
Improve Your Gas Chromatography with Backflush
Capillary Flow Technology enables flexible implementation of backflush on Agilent GCs for higher throughput, less maintenance, fewer recalibrations, longer column life, better results, and lower costs. Learn MoreGC Intelligence
Built-in GC Intelligence enables you to work smarter with autonomous monitoring, self-guided maintenance procedures, remote connectivity, and other time-saving features that can improve laboratory efficiency. Learn MoreRetention Time Locking (RTL)
Retention time locking (RTL) enables the retention times on one Agilent GC or GC/MSD system to be matched exactly on another like system using the same nominal column. Learn MoreHow It Works
Applications
Literature
- Key Literature
-
Rapid Rinse & Shoot, Screening Workflow of Pesticides in Fruit by GC/MSD in 6 Minutes
Rapid Screening Workflow for Pesticides in Fruit by GC/MSD in Under Six Minutes Using Library Search of Deconvoluted Spectra and Agilent Intuvo 9000/5977B GC/MSD- Application Notes
- English
- 28 Dec 2020
- 1.53 MB
Novel Residual Solvents Analysis of Cannabinoid Products with the Agilent Headspace-GC/MS System
This study defined a unique analytical approach specific to cannabinoid products for the analysis of residual solvents.- Application Notes
- English
- 14 Sep 2020
- 573.76 KB
Analysis of Total Petroleum Hydrocarbons in Environmental Samples Using Ultra-Fast Gas Chromatography
Analysis of Total Petroleum Hydrocarbons in Environmental Samples Using Ultra-Fast Gas Chromatography- Application Notes
- English
- 02 Aug 2018
- 676.90 KB
- Application Notes
- Brochures
- Case Studies
- Catalogs
- Data Sheets
- Flyers
- Posters
- Technical Overviews
- White Papers
Support
- FAQs
-
Frequently Asked Questions about Gas Chromatography (GC)
Learn about GC techniques and approaches that can improve performance and productivity, and get information about some of the more common troubleshooting and maintenance procedures for your GC instruments. - Firmware
- Quick Reference Guides
- Site Preparation Checklists
- Software Utilities
- Troubleshooting Guide
- User Manuals
More help is just a click away
If you didn't find what you need, try these resources or contact a specialistFeatured References
- Publications
-
- Fast Residual Solvents and Terpenes Analyses in Cannabis and Hemp Products, J. Hollis and A. Macherone, Cannabis Sci. & Tech. (2023)
- Further improvements in pesticide residue analysis in food by applying gas chromatography triple quadrupole mass spectrometry (GC-QqQ-MS/MS) technologies, E. Hakme., et al., Anal Bioanal Chem, 410, 5491–5506 (2018)
- High-throughput gas chromatography for volatile compounds analysis by fast temperature programming and adsorption chromatography, R. Gras et al., J Sep Sci., 40, 1979-1984 (2017)
- Development of a fast gas chromatography–tandem mass spectrometry method for volatile aromatic compound analysis in oenological products, M. Paolini et al., J Mass Spectrom., 53, 801– 810 (2018)
- Hydrogen-rich syngas production from palm kernel shells (PKS) biomass on a downdraft allothermal gasifier using steam as a gasifying agent, J. Barco-Burgos et al., Energy Conversion and Management, 245 (2021)
- Development and validation of a fast gas chromatography mass spectrometry method for the quantification of selected non-intentionally added substances and polystyrene/polyurethane oligomers in liquid food simulants, E. D. Tsochatzis et al., Analytica Chimica Acta, 1130, 49-59 (2020)
- Presence of anthraquinone in coffee and tea samples. An improved methodology based on mass spectrometry and a pilot monitoring programme, F. J. Díaz-Galiano et al., Anal. Methods, 13, 99-109 (2021)
- Development of a separation framework for effects-based targeted and non-targeted toxicological screening of water and wastewater, S. S. Pochiraju et al., Water Research, 170 (2020)
- Comprehensive investigation of lactones and furanones in icewines and dry wines using gas chromatography-triple quadrupole mass spectrometry, Xu Qian et al., Food Research International, 137 (2020)
- Chapter One - Comprehensive Analytical Testing of Cannabis and Hemp, A. Macherone, Comprehensive Analytical Chemistry, edited by Imma Ferrer and E. Michael Thurman, vol. 90, Elsevier, pp. 3–29 (2020)
- Ambient Condition Alcohol Reforming to Hydrogen with Electricity Output, Z. Manzoor Bhat et.al., ACS Sustainable Chem. Eng. 9(8), 3104–3111 (2021)
Tools
GC Productivity Tools
Download method translation software plus calculators for vapor volume, pressure flow, solvent vent, and CFT.GC Firmware Update Utility
Update the firmware on current and older GC systems and accessories, such as autosamplers and headspace samplers.
Prepare your lab for the arrival of your new Intuvo 9000 GC system and learn what to expect after delivery.
Helium Conservation Cost Savings Calculator
See how much helium and money you could save using Gas Saver and a helium conservation module for nitrogen standby.Essential Supplies for Gas Chromatography Systems
Use these recommended supplies for your 8900/8860/8850/Intuvo GC to help you to achieve peak performance.GC eSelector Tools
Find the appropriate columns, liners, ferrules, septa, and autosampler syringes for your GC methods.Customer Testimonials
Chantal Prat
Chemistry Area Manager, Institut Català del Suro Our new Agilent instruments have allowed us to reduce compound detection limits to a level customers want. And just as important, it has reduced analysis time. Intuvo allowed us to have very good resolution of peaks at very low concentrations. The separation is very good. Agilent instruments and columns make our work easier with simple and easy maintenance. View MoreMarli Silva de Almeida
Laboratory Specialist, Ambev This technology has brought to AmBev Laboratories an excellent improvement in the quality process of our beers. Being an extremely modern instrument, it helped us reduce our analysis time by around 50%, bringing improvements in the precision and optimization of our processes. The Agilent partnership was indispensable for the success of this project. View MoreDr. Dieter Franke
Department Manager Analytical Services, Siegwerk The plug-and-play system, without any column [trimming] and other necessary manipulation, gives the opportunity for everyone to change a column when needed, without any fear of leakages or something much worse. With the Flow Chip technology, it’s possible to split flow post-column for two different detectors or split [to different columns] before identical detectors. Within the conventional GCs, we still need re-calibration or calibration after two or five days. With the Intuvo 9000, we are going to reduce our system checking measurements. That will vastly reduce wasting time and money for non-profitable system control checks. View MoreVideos
Training & Events
Intuvo Gas Chromatography Webinars
Webinars demonstrate how the ultra-fast, intelligent Intuvo 9000 GC can improve lab productivity across a variety of application areas.
Webinar/Training
News
eBook Showcases How Agilent GC and GC/MS Systems Can Help Labs Meet Their Sustainability Goals
Access infographics, ACT labels, ESG reports, videos and more to learn how Agilent keeps sustainability in mind during the entire instrument lifecycle, from design to decommissioning. We are dedicated to helping you lower your environmental impact while maintaining lab efficiency and productivity.- 08 Apr 2024
New methods have been developed for the analysis of residual solvents and terpenes in cannabis and hemp products using a single 7697A Headspace Sampler/Intuvo 9000 GC/5977B MSD system. Results are approximately 50% and 30% faster for the solvents and terpenes, respectively, compared to the original applications. The single platform-two analyses approach has been successfully implemented in labs across North America.
- 29 Jan 2024
Experience Our Improved Online Resource for Conserving Helium or Converting to an Alternative Carrier Gas
Visit our redesigned web page for GC and GC/MS users who want to save helium or switch to hydrogen or nitrogen carrier gas. Content is organized into topic areas, making it easier to access and read the information that is most interesting and relevant to you. More literature and educational materials have been added to help you implement either approach and an FAQ section provides answers to common questions.- 15 Jan 2024
Related Products