Wide choice of modules for analytical HPLC and entry-level UHPLC
1260 Infinity II LC System
The 1260 Infinity II LC System is a robust analytical high-performance liquid chromatography (HPLC) system that offers the widest choice of modules for analytical HPLC and entry-level UHPLC analysis. This HPLC instrument delivers the performance, reliability, and robustness you need for highest confidence in your daily HPLC results.
Building on the history of the Agilent 1100, 1200, and 1260 Infinity II series analytical HPLC systems, the 1260 Infinity II LC delivers robust HPLC results while providing several ease-of-use features, making it the standard system for reliable routine HPLC analysis.
Mix and match new modules with existing HPLC instrumentation to maximize uptime and minimize disruption. The 1260 Infinity II LC system puts you on the fast track to efficiency, optimizing speed and resolution for your HPLC analysis.
Building on the history of the Agilent 1100, 1200, and 1260 Infinity II series analytical HPLC systems, the 1260 Infinity II LC delivers robust HPLC results while providing several ease-of-use features, making it the standard system for reliable routine HPLC analysis.
Mix and match new modules with existing HPLC instrumentation to maximize uptime and minimize disruption. The 1260 Infinity II LC system puts you on the fast track to efficiency, optimizing speed and resolution for your HPLC analysis.
- Analytical HPLC Systems
Product Details
Features
- Compatible with conventional and ultra-high performance liquid chromatography (UHPLC): 1260 Infinity II Quaternary Pump and 1260 Infinity II Binary Pump operate up to 600 bar, a perfect match for our InfinityLab Poroshell 120 columns
- Efficient control, acquisition, and reporting: the Agilent instrument control framework enables smooth control of Agilent HPLC instrumentation through third-party chromatography data systems
- Fast and precise gradients: the 1260 Infinity II Binary Pump is the perfect choice for fast and precise gradients using LC/MS, as well as UV-only systems
- Ultralow carryover: the Multiwash capability of the 1260 Infinity II Multisampler cleans all relevant injection parts between runs, flushing the injection needle outside with three solvents using seat backflush procedures to reduce carryover to less than 10 ppm
- Reduced cycle times: with the dual-needle design, run samples alternate through one or the other injection path, reducing cycle times to mere seconds, virtually eliminating conventional wait times - whether for large volume loadings or flushing procedures
- Analytical and semipreparative purifications: wide flow range of the 1260 Infinity II Quaternary Pump (up to 10 mL/min) perfectly supports standard and semipreparative applications
- Efficient sample handling and logistics: using shallow well-plate drawers, the 1260 Infinity II Multisampler takes a maximum load of 16 microtiter plates and up to 6,144 samples - the most of any single system
- Efficient HPLC column handling/temperature control: the 1260 Infinity II Multicolumn Thermostat holds up to four columns with direct access to each column through a quick-change switching valve for flexibility/eliminating the need to disconnect/reconnect columns
- Higher quality data: the 1260 Infinity II Diode Array Detector HS delivers lower detection limits and higher data quality for more confidence
- Your choice for performance and sustainability: The 1260 Infinity II LC System has received the My Green Lab ACT (Accountability, Consistency, Transparency) label after an independent audit to verify its environmental impact throughout the product life cycle.
Specifications
Column Capacity |
|
Column ID Reader Option |
|
Depth |
|
Flow Range |
|
Injection Range |
|
Intelligent System Emulation Technology |
|
Line Voltage |
|
Maximum Number of Solvents |
|
Maximum Number of Temperature Zones |
|
Pump Type |
|
System Pressure Operating Range |
|
Width |
|
System Components
- Mobile Phase Delivery
-
1260 Infinity High Performance Degasser
High-performance degassing at up to 5 mL/min for low-flow applications and analytical LC.1260 Infinity II Binary Pump
Binary solvent delivery at pressures up to 600 bar and flow rates up to 5 mL/min.1260 Infinity II Degasser
High-capacity degassing at flow rates up to 10 mL/min for GPC/SEC and other high-flow applications.1260 Infinity II Flexible Pump
A quaternary UHPLC pump with solvent delivery at pressures up to 800 bar and flow rates up to 5 mL/min.1260 Infinity II Quaternary Pump
Quaternary solvent delivery at pressures up to 600 bar and flow rates up to 10 mL/min. - Sample Introduction
- Column Handling
- Detection
- Recommended Accessories
- Application Software
How It Works
Applications
Literature
- Key Literature
-
Detection, Confirmation, and Quantitation of Chloramphenicol in Honey
Describes use of the Agilent 1260 Infinity II LC with the Agilent Ultivo LC/TQ to achieve very low picogram quantities of chloramphenicol in honey samples.- Application Notes
- English
- 11 Sep 2019
- 644.56 KB
The LC Side of "Do More with Less"
This eBook features unique Agilent InfinityLab LC Solutions developed to solve the everyday, but certainly not “routine”, problems in the modern laboratory.- Brochures
- English
- 17 Jan 2020
- 5.63 MB
Agilent 1260 Infinity II LC Brochure
The Agilent 1260 Infinity II LC offers the broadest choice of instrumentation while giving you the best operational efficiency – every day in every way- Brochures
- English
- 31 May 2016
- 2.38 MB
- Application Notes
- Brochures
- Flyers
- Posters
- Selection Guides
- Technical Overviews
Support
- Support
-
Agilent Supplies for the Agilent 1260 Infinity LC
Agilent Technologies is committed to optimizing your laboratory’s productivity, so we have produced this list of the most commonly ordered supplies and parts for the 1260 Infinity Binary, Quaternary and Isocratic LC Systems.- Quick Reference Guides
- English
- 30 Oct 2018
- 233.43 KB
Agilent InfinityLab LC Series Site Preparation Checklist
InfinityLab LC Series Site Preparation Checklist (Rev. C.04)- Site Preparation Checklists
- English
- 15 Mar 2024
- 2.23 MB
- FAQs
- Quick Reference Guides
- Supplemental Information
- User Manuals
Featured References
- Publications
-
- Complexity Begets Collaboration. With new achievements and changes every month – from personalized medicines to artificial intelligence and automation – it is becoming increasingly challenging for the biopharmaceutical industry to keep up. The Analytical Scientist spoke with Jennifer R?mer (expert in mass spectrometric protein characterization at Rentschler Biopharma SE, Laupheim – a contract development and manufacturing organization (CDMO) for biopharmaceuticals, including advanced therapy medicinal products (ATMPs) and Jens Meixner (product manager for CE and HPLC systems at Agilent Technologies) to find out more about the challenges faced by users and manufacturers alike – in a rapidly evolving world. 05/24/2024
Tools
Explore customer reviews posted on SelectScience, or write your own review.
Agilent InfinityLab HPLC Advisor
This one comprehensive app provides tools and information for your daily HPLC workflow.Essential Supplies Guide for InfinityLab LC Series Instruments
Discover the right supplies for your instrument to achieve peak performance and optimize your LC workflow.HPLC/UHPLC Application Finder
Search for HPLC and UHPLC Application Notes and Technical Overviews.Videos
News
Agilent Technologies has achieved a Silver Seal of Quality for its 1260 Infinity II LC System. Seals of Quality by SelectScience recognize the top 0.1% of products that consistently receive the highest customer review ratings.
- Seal of Quality Awarded to the Agilent 1260 Infinity II LC System
- 27 Oct 2022
Related Products
Promotions