The Agilent 4300 Handheld FTIR
4300 Handheld FTIR Spectrometer
The Agilent 4300 Handheld FTIR spectrometer incorporates lightweight ergonomics, ease of use, ruggedness, and flexibility in one system. Weighing only ~2 kg, it is ideal for mobile nondestructive testing in field and nonlaboratory environments.
The 4300 system allows novice and experienced users alike to quickly analyze on the go, due to its high-performance optics, hardware design, and easy-to-use MicroLab Mobile software. Users can easily transition from one sample to another, with no alignment or adjustments necessary, simply by changing the sampling interface. Applications include analysis of polymers, coatings, composites, bulk material, cleaning verification, and even historical artifacts and artwork.
The 4300 system allows novice and experienced users alike to quickly analyze on the go, due to its high-performance optics, hardware design, and easy-to-use MicroLab Mobile software. Users can easily transition from one sample to another, with no alignment or adjustments necessary, simply by changing the sampling interface. Applications include analysis of polymers, coatings, composites, bulk material, cleaning verification, and even historical artifacts and artwork.
- Compact & Portable FTIR Systems
Request a Quote
Product Details
Features
- True mobile nondestructive testing of advanced materials
- Ergonomic handheld FTIR spectrometer design for ease of use and optimal data measurement
- On-the-go sampling flexibility with auto-recognized, interchangeable sample interfaces
- DGTS detector delivers broad spectral coverage for routine analysis
- MicroLab Mobile FTIR software reflects the design of the mobile measurement hardware: powerful, reliable, simple to use, and focused on the answers you need
- Optional MicroLab Pharma supports compliance with data integrity regulations
- Intuitive, method-driven, multilanguage software guides users through every step of operation, while color-coding alerts make it easy to see whether samples meet specifications
- MicroLab Quant provides a simple, guided quantitative methods development package
Specifications
Control Software |
|
Depth |
|
Height |
|
Libraries |
|
Power Requirements |
|
Resolution |
|
Sample Type |
|
Sampling Modules (interchangeable) |
|
Spectral Range |
|
Type |
|
Weight |
|
Width |
|
Technology
Reflectance FTIR Spectroscopy
Reflectance FTIR is used to acquire high quality spectral data from solid samples. Specular reflection is used with reflective surfaces, diffuse reflection (DRIFTS) works with rougher, less reflective surfaces (often powders), and reflection-absorption grazing angle FTIR measures sub-micron thin films and contaminants on surfaces. Learn MoreLiterature
- Key Literature
-
Agilent 4300 Handheld FTIR Spectrometer Brochure
At-site. Immediate results. True non-destructive analysis. Perform accurate, non-destructive material testing with the Agilent 4300 Handheld FTIR.- Brochures
- English
- 01 Mar 2014
- 4.56 MB
Non-Destructive Analysis of Substrates and Contaminants by FTIR Specular Reflectance
Agilent 4300 handheld FTIR spectrometer with specular reflectance identifies substrate materials, evaluates presence of contaminants, quantifies contaminants.- Application Notes
- English
- 24 May 2023
- 2.13 MB
Applications of FTIR Throughout Lithium Ion Battery Life Cycle
Overview of the materials in the LIB value chain that can be analyzed by the Agilent 4300 handheld FTIR spectrometer.- Application Notes
- English
- 17 Aug 2023
- 251.52 KB
- Application Notes
- Brochures
- Catalogs
- Data Sheets
- Flyers
- White Papers
Support
- FAQs
-
FTIR Spectroscopy, Infrared Spectroscopy—FAQs
Learn about infrared spectroscopy & FTIR spectroscopy—FAQs on how FTIR works, how FTIR spectrometers work, FTIR measurements, and techniques like ATR-FTIR - Site Preparation Checklists
- Supplemental Information
- User Manuals
More help is just a click away
If you didn't find what you need, try these resources or contact a specialistNews
Agilent Releases MicroLab 5.8, MicroLab Pharma 5.8, and MicroLab Expert 1.3
The new revision of software that powers the Cary 630 FTIR spectrometer—as well as Agilent handheld and mobile FTIR systems—is now supported on Microsoft’s latest operating system – Windows 11. The MicroLab Pharma 5.8 software now also utilizes Microsoft SQL Server 2022 Express, supported by Microsoft until 2028.- 31 May 2024
Primer - Agilent Solutions for the Lithium-Ion Battery Industry
Unclear where to begin your lithium-ion battery testing journey? Need clarity on how to address multiple testing needs? Read Agilent's introductory guide to mineral, processing, cell component, and leak testing solutions and set your lab up for success.- 19 Dec 2023
Agilent Releases FTIR Narcotics Identification Capability
A new comprehensive library (TICTAC FTIR ATR drugs library) is now available for deployment with aozhou2n.compact and portable FTIR systems for drug identification applications. The new library contains 643 drugs and drug related substances with focus on new psychoactive substances (NPS), and is paired with the new features in Agilent’s application-focused FTIR software, MicroLab, to provide a simple, fast solution for drug ID.- 31 Jul 2022
Tools
FTIR Analysis & Applications Overview
A guide to modern applications of FTIR analysis using benchtop and handheld instruments.Videos
Featured References
- Publications
-
- Total and Hot-Water Extractable Organic Carbon and Nitrogen in Organic Soil Amendments: Their Prediction Using Portable Mid-Infrared Spectroscopy with Support Vector Machines, R. Wehrle, G. Welp, S. Patzold, Agronomy, 2021 (11), 659.
- Microplastics in Marine and Estuarine Species From the Coast of Portugal, J. Pequeno, J. Antunes, V. Dhimmer, F. Bessa, P. Sobral, Front. Environ. Sci., 2021 (9), 18.
- Application of Infrared Reflectance Spectroscopy on Plastics in Cultural Heritage Collections: A Comparative Assessment of Two Portable Mid-Fourier Transform Infrared Reflection Devices, E. M. Angelin, M. Bacci et al., Applied Spectroscopy, 2021, 75 (7), 818-833.
- Investigation of an alternative approach for real-time cleaning verification in the pharmaceutical industry, E. Moore, A. Sarwar, C. McSweeney, M. Smith, J. Timmermans, Analyst, 2020,145, 7429-7436.
- The application of rapid handheld FTIR petroleum hydrocarbon-contaminant measurement with transport models for site assessment: A case study, L. Wang, Y. Cheng, D. Lamb, R. Naidu, Geoderma, Volume 361, 2020, 114017.
- A non-invasive screening study of varnishes applied to three paintings by Edvard Munch using portable diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS), Ford, T., Rizzo, A., Hendriks, E. et al., Herit. Sci. 7, 84 (2019).
Training & Events
Molecular Spectroscopy Webinar Curriculum
Molecular Spectroscopy Webinar Curriculum includes UV-Vis, UV-Vis-NIR, fluorescence, handheld and benchtop FTIR, and Raman systems for high performance and flexibility
Webinar/Training
Spectroscopy Digital Workshops & Bootcamps
Hone your lab skills, outside the lab, with our live, interactive series of virtual workshops and software bootcamps! Learn about the latest in software solutions for Spectroscopy, discuss the entire analytical process from method development to data analysis, and participate in live analytical runs with our experts. We hope these will prepare you for future hands-on events in the future.
Webinar/Training
Related Products
Promotions