xCELLigence RTCA HT - ?????? ??
RUO
Agilent xCELLigence?Real-Time Cell Analysis (RTCA) HT ??? label-free ?? ????? ??? ?? ???, ?? ? ????? ?? ??, ??, ??? ????? ???????.???? ????? ??, ??? ??? ?, ?? ??? ?? ????? ????? ?? ? ??? ? ?? ??? ?? ?? ????? ??? ???? ?? ? ????.?
xCELLigence RTCA HT ??? BioTek BioSpa 8 ?? ?????? ??? RTCA HT ??? ???? ???? 3,072? well? ????, ??? ? ???? ?? ???? ??? ??? ??, ??? ???, ?? ?? ????? ?????.
? HT ??? 384-well ??? ????????(E-Plate 384)? ??? ? ???, ?? ???? ??? ???? ??? ?????. ?? ?? ???? ???? ?? 4?? ??? ???? ? 1,536? well?? ?? ?? ?? ?? ???? ??? ??????. RTCA HT ??? ?? ??? ???? ?? ??? ?????, ???? ?? ??? ?? ?? ?? ?? ?? ?? ????? ??? ? ????.
xCELLigence RTCA HT ??? BioTek BioSpa 8 ?? ?????? ??? RTCA HT ??? ???? ???? 3,072? well? ????, ??? ? ???? ?? ???? ??? ??? ??, ??? ???, ?? ?? ????? ?????.
? HT ??? 384-well ??? ????????(E-Plate 384)? ??? ? ???, ?? ???? ??? ???? ??? ?????. ?? ?? ???? ???? ?? 4?? ??? ???? ? 1,536? well?? ?? ?? ?? ?? ???? ??? ??????. RTCA HT ??? ?? ??? ???? ?? ??? ?????, ???? ?? ??? ?? ?? ?? ?? ?? ?? ????? ??? ? ????.
?????? ??????. ?? ???? ???? ? ????.
- RTCA Analyzers
Request a Quote
No data to display
This product is not available for purchase by the general public.
Product Details
Features
- xCELLigence RTCA HT ??? 1?? 384-well plate? ??? ? ???, ?? 4?? ???? ? 1,536?? well?? ?? ?????
- xCELLigence RTCA HT ??? BioTek BioSpa 8 ?? ?????? ???? ?? 8?? 384-well E-Plate? ?? ???? ??? ?????(? 3,072?? well).
- ? ??? ?? ??, ??? ? ????? ?? ??, ?? ??? ?? ??? ?? ??? ?????
- ???? label-free ??? ???? ??? ?? ?? ????? ?? ???? ?? ? ????(? ??? ? ???)?
- ??? ????? ?? ???? ???? ?? ?? ???? ???? ???? ??? ??? E-plate? ???? ??? ??? ??? ? ??????
- ?? ???? ??? ??? ??, ??? ???, ?? ?? ????? ?????.
Technology
?? ???? ??
?? ???? ??? ?? ??? Microtiter plate well ?? ??? ??? ??? ?? ????(gold microelectrodes)???. ?? ??? ??(??? ?? ?? ?? ?? ??)? ??? ??? ??? ??? ???? ??? ?? ??? ?? ?? ??? ??? ?? ?? ??? ???? ??? ?????. Learn MoreHow It Works
Applications
Literature
- Application Notes
-
xCELLigence Portfolio Cancer Immunotherapy Handbook
Recently updated Cancer Immunotherapy Handbook featuring the latest high impact xCELLigence publications and newly released supporting information.- Application Notes
- English
- 10 Mar 2023
- 10.21 MB
Evaluating Functional Potency of Immunotherapies Targeting Tumors of B Cell Origin
Describes use of a tethering approach to immobilize liquid tumor cell lines on to the surface of gold biosensors embedded in an Agilent E-Plate.- Application Notes
- English
- 03 Jun 2022
- 1.10 MB
High-Throughput GPCR Assay Development
This application note demonstrates how the xCELLigence system can run GPCR assays without expressing additional reporter proteins.- Application Notes
- English
- 12 Feb 2021
- 1.80 MB
A New Way to Monitor Virus-Mediated Cytopathogenicity
This application note describes the experimental setup for assessing vesicular stomatitis virus-mediated cytotoxicity of Vero E6 cells and HEK 293 cells using an xCELLigence instrument.- Application Notes
- English
- 12 Feb 2021
- 358.59 KB
Label-Free Assay for NK Cell?Mediated Cytolysis
In this application note, a series of experiments demonstrate how the xCELLigence RTCA system can be applied to quantitatively monitor NK cell?mediated cytolysis without labeling the target cells.- Application Notes
- English
- 12 Feb 2021
- 699.12 KB
Dynamic Monitoring of Receptor Tyrosine Kinase Activation in Living Cells
This application note highlights the development and utility of an alternative receptor tyrosine kinase assay that uses the impedance?based xCELLigence system.- Application Notes
- English
- 12 Feb 2021
- 1.58 MB
Dynamic Monitoring of G-Protein?Coupled Receptor Activation in Living Cells
In this application note, a series of experiments demonstrates how the xCELLigence system may be used to monitor functional activation of GPCRs in living cells.- Application Notes
- English
- 12 Feb 2021
- 1.07 MB
Dynamic Monitoring of Cell Adhesion and Spreading
In this application note, a series of experiments is described to demonstrate that the xCELLigence system is suitable for monitoring cell adhesion and spreading.- Application Notes
- English
- 12 Feb 2021
- 1007.33 KB
Real-Time and Dynamic Monitoring of Cell Proliferation and Viability for Adherent Cells
This application note shows experiments that were conducted using xCELLigence instruments to assess cell proliferation and drug interaction with different cell lines.- Application Notes
- English
- 19 Aug 2020
- 1.00 MB
Vaccine and Virology Applications
A collection of studies showing the benefits of xCELLigence RTCA assays over traditional assays. Antiviral drugs, virucides, neutralizing antibodies and other applications are examined.- Application Notes
- English
- 02 Jul 2020
- 4.37 MB
- Article Reprints
- Brochures
- Case Studies
- Data Sheets
Support
- Instruction Sheets
-
Dell Ownership Transfer Process
Dell Ownership transferring process- Instruction Sheets
- English
- 24 Aug 2020
- 417.41 KB
- Quick Reference Guides
- User Manuals
Didn’t find what you need? Contact our dedicated Cell Analysis support teams.
Tools
SelectScience? ??? ?? ?? ????
???? ?? ?? ??? ??????
?? ??, ?? ?? ? ??? ?? ????? ??????.Videos
Training & Events
Related Products
Promotions