JetClean 智氫潔離子源
Agilent JetClean 智氫潔離子源可大大減少甚至消除手動清潔離子源的需求,從而最大程度延長儀器的正常運行時間、提高樣品通量,每月可多出 1–2 天的分析時間。對于開展包含復雜基質的食品、環境、化學、法醫學和材料分析的高通量實驗室而言,免維護離子源可顯著提高實驗室效率。用戶反饋證實,清潔周期可從每 2 周一次減少到每 3–6 個月一次,甚至更少。
Agilent JetClean 離子源利用軟件控制的氫氣流來減少或防止污染物積聚并消除離子源中的基質沉積物。JetClean 的自動清潔離子源功能不僅可以延長儀器的正常運行時間,還可以生成更加一致的數據、減少重復工作,讓您在節省成本的同時對結果更加充滿信心。
Agilent JetClean 離子源利用軟件控制的氫氣流來減少或防止污染物積聚并消除離子源中的基質沉積物。JetClean 的自動清潔離子源功能不僅可以延長儀器的正常運行時間,還可以生成更加一致的數據、減少重復工作,讓您在節省成本的同時對結果更加充滿信心。
- GC/MS Ion Sources & Inlets
Request a Quote
No data to display
This product is not available for purchase by the general public.
Product Details
Features
- 手動清潔頻率降低 80% 或更多(取決于具體應用),顯著延長免維護運行周期
- 顯著縮短甚至消除儀器在放空、拆卸、清潔、重新組裝、重新調諧和重新校準上所耗費的時間,延長儀器正常運行時間,減少操作人員的工作量,從而提高效率
- 無需人工干預,即可在預設時間點自動激活 JetClean,例如在空閑時間段內
- 使用?采集和清潔?(并行)模式在分析期間進行清潔,或使用?僅清潔?(運行后)模式,僅在系統需要清潔時,在采集后引入氫氣進行清潔
- 僅需消耗極少的 H2。氫氣可以通過氣閥瓶等多種方式提供。
- 操作均由 Agilent MassHunter 軟件控制,從而可輕松實現采集控制、方法開發、定性和定量分析以及報告。單四極桿儀器也由 OpenLab 2.3 軟件進行類似控制
- 適用于 Agilent 5977C、7000E 和 7010D GC/MS 系統。Agilent Intuvo、8890 和 7890 GC 也可兼容 JetClean 運行
- 可作為現有 Agilent 5975、5977、7000 和 7010 氣質聯用系統的升級
Literature
- Key Literature
-
Agilent JetClean self-cleaning ion source for GC/MS e-book
Save Time and Money with the Agilent JetClean Self-Cleaning Ion Source for GC/MS- Brochures
- English
- 05 May 2021
- 642.18 KB
- Application Notes
- Brochures
- Case Studies
- Flyers
- Posters
Tools
JetClean 成本計算器
衛生期限延長 90% 后,研究室將節約開支大小資金?Customer Testimonials
Dr. Noga Sikron Persi, PhD
Ben-Gurion University Metabolomics Laboratory "The nature of our work meant we had to clean the ion source on our previous, non-Agilent GC/MS about once every 2 weeks. Since we started using the Agilent GC/MSD with JetClean, the source has been cleaned once in 9 months meaning our instrument spends more time running samples and generating data—and our users spend less time having to remove, clean, and reinstall the source. JetClean has been a tremendous benefit on instrument uptime and lab productivity." View MoreJana Pulkrabova, PhD
Head of the Department of Food Analysis and Nutrition, University of Chemistry and Technology, Prague "Our laboratory carries out pesticide residue analysis with the Agilent 7000 GC/MS/MS. The samples include common fruits and vegetables, but we also analyze more difficult herbal samples, and monitor baby food, which has lower detection requirements. To satisfy SANCO defined QA/QC specifications with these varied samples, the GC/MS source usually had to be cleaned every 2 weeks. After installing the JetClean system, the frequency of the manual source cleaning has been greatly reduced, we now manually clean the source only once in every 3 months. This increased productivity and freed up operator time is greatly appreciated." View MoreKlaus Wilmers, PhD
Chemical and Veterinary Analytical Institute Muensterland-Emscher-Lippe (CVUA-MEL), Muenster, Germany "We analyzed the EN QuEChERS in various food extracts – e.g. chard, apple, plum, peppers and spinach in the working range of 0.1 – 250 ppb (in vial) using internal standards, Analyte Protectants and employing the high efficiency source. Without JetClean, manual source cleaning was needed after 200-300 matrix runs. Applying JetClean after each run, manual cleaning was only needed after 600-900 matrix runs, thus, instrument up-time was increased by several-fold and associated cost-savings were realized." View MoreVideos
Related Products
Promotions